How to ensure the performance of Buckling Restrained Brace under high - temperature conditions?

Nov 22, 2026Leave a message

Buckling Restrained Brace

Unbonded Buckling-restrained Energy-dissipation Braces

Hey everyone, I'm Sam, the tech lead here at our BRB supply team, and today I wanna talk about something that's been popping up in our client meetings nonstop lately: how to keep Buckling Restrained Braces (BRBs) performing when things get seriously hot. If you're in structural engineering, you know BRBs are those workhorse devices that stop buildings from shaking apart during earthquakes-they hold tension and compression without buckling like regular steel braces, right? But here's the thing: when you're dealing with high temps-think wildfires, industrial facilities with near equipment, or even urban areas where heat islands crank ambient temps way above standard test conditions-those BRBs can lose their edge if they're not set up right. Over the last few years, we've tested dozens of modified BRBs in our lab and worked with 12+ industrial clients on projects with brutal heat, so I've got real, actionable tips here, not just textbook jargon.

 

 

 

 

First, let's get why heat messes with BRBs in the first place, because you can't fix a problem you don't fully get. A standard BRB has two core parts: a steel core that carries all the load, and an outer restraining casing (usually concrete or mortar-filled steel tube) that keeps the core from buckling when it's compressed. Steel's yield strength drops when it's hot-like, a steel core that's rated for 350 MPa at room temp can be 20% weaker at 300°C, and 50%+ weaker if it hits 500°C. But wait, it's not just strength: the bond between the core and the casing can break down at high temps, too. If the mortar or concrete gets brittle from heat, it stops evenly restraining the core, so the core might buckle anyway. And if you're in a place with cyclic heat-like a factory that's 120°F during the day and drops to 60°F at night-you get thermal fatigue, which causes cracks in the casing way before earthquake loads even hit. That's a big mistake I see a lot: engineers test BRBs at room temp, sign off, then they fail during a summer wildfire or a plant heat spike.

So what have we learned from our lab and field tests? Let's break down the non-negotiable steps.

First, spec the right core material. Not all steel is created equal for heat. We used to stick to standard A36 steel for BRB cores, but now for high-heat projects, we're pushing alloy steels with higher tensile and yield strength retention at elevated temps-like A572 Grade 50 modified with chromium and vanadium additives. These alloys don't just hold their strength longer when hot; they also have better ductility, so they can flex and absorb energy without cracking when temps swing. We tested one alloy core at 400°C and its yield strength only dropped 12% (vs. 38% for standard A572), which was a game-changer for a chemical plant client last year. Pro tip: ask your supplier for core material's hot strength curve, not just room temp specs-if they can't give you that, keep looking.

Next, the restraining casing is make-or-break. We used to use plain concrete, but at our lab, we found that high-strength fiber-reinforced concrete (FRC) works way better for heat. The micro steel or polypropylene fibers in FRC prevent the concrete from cracking when it expands with heat, so the bond between core and casing stays intact. We also do a thing where we add a thin layer of intumescent coating to the inner wall of the casing-this is a coating that swells when it hits heat, creating an insulating foam that slows down heat transfer to the steel core. For example, in a test where we hit a BRB with 500°C for 2 hours, the intumescent coating kept the core temp at 280°C vs. 420°C for an uncoated casing. No more sudden strength drops mid-event. Another thing we do: gap control. If the core expands as it heats, it needs a little room to grow without pushing against the casing too hard, so we add a 1mm to 2mm gap between the core and casing filled with a high-temperature lubricant (like graphite-based grease that stays stable up to 600°C). Too small a gap, and thermal expansion causes the casing to crack; too big, and the core doesn't get enough restraint. We've fine-tuned this gap size after 27 rounds of testing, so it's a precise spec now.

Wait, but what about projects where there's already other vibration mitigation gear? I've had clients ask, "Should I pair BRBs with other devices instead of modifying BRBs themselves?" And honestly, it depends on the heat level. If you're in an area with moderate heat (like 150°F max), combining BRBs with Lead Viscoelastic Damper(LVD) makes sense. LVDs handle cyclic loads and add damping, so they reduce the amount of energy the BRB has to absorb, which keeps the BRB's temp lower during an earthquake. For extreme heat (like near a steel mill where temps hit 300°C consistently), we pair BRBs with Friction Damper too? Wait no, wait-friction dampers work well for heat because their damping comes from steel pads rubbing, not rubber or concrete that breaks down. Wait, no, let's be clear: we use friction dampers as supplementary energy absorbers in high-heat zones, so the BRB's main core isn't taking all the load. Also, if your project uses rubber bearings for seismic isolation, like Pot Rubber Bearing or Space Truss Rubber Bearings, those rubber parts do degrade at high temps-so if you're combining BRBs with those, you need to either upgrade the rubber to heat-stable nitrile or silicone, or make sure the BRBs are sized to handle extra seismic load if the bearings lose a little performance. Wait, and for super long-span structures, we've used Tuned Mass Damper (TMD) paired with BRBs too-TMDs handle wind-induced vibration, which can build up heat in BRBs over time, especially in coastal high-wind areas, so that's a good combo for non-seismic heat-related wear. But back to BRB-specific stuff, because that's the topic here.

Another big mistake we see is installation gaps. If you install a BRB too tight or not aligned right, when it heats up, the thermal expansion causes residual stress that bends the core slightly, which makes it buckle earlier during a seismic event. We developed a custom installation guide for high-heat projects: after installing, we heat the BRB uniformly to the project's design max temp using infrared heaters, then adjust the end connectors to take up the gap that forms. That way, when the real event hits, the BRB is already at operating temp, no extra stress from uneven expansion. We did this on a data center project in Phoenix last year, where ambient temps hit 118°F in summer, and their BRBs passed all thermal seismic tests with zero issues.

Wait, what about regular maintenance? BRBs don't set it and forget it, especially in high-heat areas. We tell clients to do annual checks: look for cracks in the casing, check the gap for debris (debris can get stuck and mess with thermal expansion), and use a pyrometer to check core temp spikes during hot summer months. If you spot a tiny crack in the casing, you can inject a heat-resistant epoxy to seal it, which keeps the core-casing bond intact. We also recommend replacing the graphite lubricant every 3 years in high-heat zones, because it can dry out or get contaminated with dust.

Let me share a real fail story to drive this home. A client in Southern California (big heat islands, wildfire risk) installed standard BRBs on a commercial building, no modifications. Last summer, a wildfire 2 miles away raised ambient temp by 40°F for 12 hours. During a small earthquake that hit that week, 3 of the 12 BRBs buckled. We did a post-mortem: the core temp hit 420°C, which made its yield strength drop too much, and the plain concrete casing had micro cracks from thermal expansion, so it didn't restrain the core. We retrofitted those BRBs with FRC casings, intumescent coating, and modified alloy cores, and they passed our thermal seismic test (we ran it at 400°C for 2 hours, then a full seismic load test) with no issues. Now that client has us on retainer for all their other high-heat projects.

What's the bottom line here? Ensuring BRB performance in high temps isn't about guessing-it's about specifying the right materials, fine-tuning the casing and gaps, pairing with supplementary vibration gear if needed, installing correctly, and doing regular checks. You can't rely on off-the-shelf BRBs if your project is in a hot environment; you need to adjust the spec for the exact temp conditions, whether that's industrial heat, urban heat islands, or wildfire zones.

If you're working on a project that's dealing with high temps or wondering if your current BRB setup is up to snuff, feel free to reach out to our team to talk through the details. We've got lab data, field test results, and experience with all kinds of high-heat scenarios, so we can help you spec the right solution that keeps your structure safe when the temp rises and when the ground shakes.


References

  1. ASCE 7-16, Minimum Design Loads and Associated Criteria for Buildings and Other Structures, American Society of Civil Engineers, 2016.
  2. Eurocode 8: Design of structures for earthquake resistance – Part 1: General rules, seismic actions and rules for buildings, European Committee for Standardization, 2004.
  3. Li, Y., et al., "Performance of Buckling-Restrained Braces at Elevated Temperatures," Journal of Structural Engineering, Vol. 145, No. 10, 2019, pp. 04019108.
  4. GB 50011, Code for Seismic Design of Buildings, Ministry of Housing and Urban-Rural Development of the People's Republic of China, 2010.
  5. AASHTO LRFD Bridge Design Specifications, American Association of State Highway and Transportation Officials, 2020.