Q: 1, What is earthquake isolation?
A: Earthquake isolation (also called seismic isolation, seismic isolation or base isolation) is a system that protects the structure and all components inside the structure from the destructive effects of earthquakes by creating a layer between the structure and the ground, thanks to special devices (earthquake isolation devices) placed between the structure itself and its foundation. Earthquake isolators (also called earthquake isolation devices, seismic isolators or base isolation devices) are placed in the structures, one for each column and more than one under the curtain walls, and the superstructure is separated from the foundation and the ground.
Q: 2, How does earthquake isolation Work?
A: Earthquake insulation increases the period of the structure to which it is applied, thanks to the flexibility of the devices in the lateral direction, and meets the horizontal displacement demand that will occur in the event of an earthquake at the isolator interface (with earthquake insulation devices). In addition, the damping rate, which is accepted as 5% in normal buildings, plays an extra role in reducing the destructive effects of earthquakes by increasing 20% or more when it comes to earthquake insulation.
Q: 3, What are the benefits of earthquake isolation?
A: Earthquake insulation protects both the structural and non-structural elements of the superstructure and thus ensures that the structure survives any earthquake with zero damage and remains fully functional. Earthquake isolation is the only proven and applicable method that can simultaneously control the relative storey drifts and storey accelerations in a building. In addition, earthquake insulation is the only method that ensures that the structure and all its components (structural and non-structural elements) survive the largest earthquake expected in the region with zero damage, thus guaranteeing the uninterrupted use of the structure after any earthquake.
Q: 4, How do non-structural details change in earthquake isolation application?
A: Since the structure is completely separated from the ground next to the isolator, the mechanical details (all connections such as electricity-water-waste-natural gas) should also be supported with special details to be suitable for earthquake insulation and movement in all directions. Such special applications are commercially available.
Due to the fact that the earthquake-proofed building is built in a way that it can move freely in all directions in the event of a possible earthquake, it will be completely separated from the ground and a space will remain around the structure. This gap must be crossed with all-round joints. Again, standard joints produced for such applications are easily available in the market.
Q: 5, How should the building architecture be in the application of earthquake isolation?
A: In buildings planned to be built with earthquake isolators, the structure should be designed and modeled as insulator starting from the architecture. For example, the dimensions of the columns where the insulators will be placed should be adjusted with calculations and the general architecture should also be determined in accordance with the insulator application. Architectural approach and design in buildings with and without insulators are different from each other, and an insulator cannot be applied to an architecture that is planned and prepared without insulators. For this reason, a structure that is planned to be applied with an earthquake isolator should be solved with an appropriate architecture from the beginning. For example, in earthquake-proof buildings, it should be preferred to use square column and beamed frames instead of thin long column / curtain type carrier systems and non-beam slabs.
Q: 6, How to make static calculations in earthquake isolation application?
A: After the architectural solutions of the building are adjusted to be compatible with the earthquake isolator application, static calculations can be made more effectively. Similarly, static calculations should be made with structural analysis programs that have earthquake isolator models, have the capacity to perform linear and nonlinear analyzes and have proven themselves in this field.
Before starting the static calculations, the design acceleration spectra to be taken from National Earthquake Hazard Map published by your government, as well as site-specific earthquake hazard analyzes should be made by experts and the calculations of the structure in question should be started after that.
Q: 7, How is the field installation of earthquake isolation devices made?
A: It is very important that the insulators are mounted to their respective places in the field by expert teams in this field. The assembly of these devices must be done very precisely and carefully. Otherwise, no matter how correct design and production is made, it is very difficult to reverse an error that will occur during assembly.
Q: 8, Can savings be provided in the building by applying earthquake insulation?
A: When earthquake insulation is applied to a building, it cannot be expected that a size or reinforcement savings will be achieved in the structural elements. In some cases, there may be savings such as reducing the size of the superstructure elements and reducing the amount of reinforcement, but this may vary for each structure and must be checked with calculations.
Q: 9, Can earthquake isolation be used for reinforcement?
A: Earthquake insulation can be used not only in new constructions but also in reinforcement applications. However, beforehand, it is obligatory for an expert team to make an evaluation in order to understand whether the structure is suitable for earthquake insulation and retrofitting.
For more detailed information, you can get in touch with us, we have a professional team to provide a valued advisor and solutions for your building or structures.
Q: 10, How many types of earthquake isolation devices are there?
A: There are basically 5 types of insulation devices used in the world to provide earthquake insulation: lead core rubber type (LRB), Linear Nature rubber bearing(LNR), Friction pendulum system type (FPS), highly damped rubber type (HDRB), and Elastic Sliding Bearing(ESB). These bearing are adopted in different application conditions according to the buildings or structures. You can find these products detail in our products "seismic isolation products". If you have any doubt, please get in touch with us.
Q: 11, Do earthquake isolators require control?
A: Periodic checks of earthquake isolators should be made. Control procedures determined specifically for the structure should be applied.
Q: 12, Do earthquake isolators require maintenance?
A: Earthquake isolators do not require maintenance under normal conditions.
Q: 13, Do earthquake isolators have a warranty?
A: The standard warranty period of earthquake isolators is 10 years. Warranty periods may vary depending on the project.
Q: 14, What are the dimensions of earthquake isolators?
A: Dimensions and weights of insulators are highly variable and are designed specifically for the project. The design of the insulators varies depending on many factors such as the weight of the superstructure, the vertical load on each insulator, the seismicity of the area where the building is located, the concrete class used in the building, the performance target of the building, and the architecture. Accordingly, earthquake isolators can be either 50 cm in diameter or 200 cm in diameter.
Q: 15, What are the stages to be followed in earthquake insulated projects?
A: ØIn New Buildings:
Insulator application is done in the following order in new constructions:
• Performing soil analysis.
• Site-specific earthquake hazard analysis, control and approval of the analysis.
• Preparation of the architecture.
• Determination and getting approval for architecture before starting static calculations.
• Preparation of static projects with insulators and preliminary analysis.
• The isolator manufacturer's design of isolators according to preliminary static analyses, structural properties and seismicity (determination of insulator budgetary costs).
• Analyzing and checking the static project once again with the final isolator parameters, making corrections if necessary and finalizing the project.
• Production and quality control tests (prototype and production tests) of insulators. With these tests, the design parameters of the insulators are verified.
• Installation of insulators on site.
• Completion of superstructure construction.
• The licensing and approval processes are also progressing at this time. In addition, the awareness of the systems in the sector has increased, especially with the applications that started with hospitals, and this has facilitated the approval processes.
ØThings to consider for retrofit projects with insulators:
• It cannot be applied if the structure is adjacent or it should be applied to all adjacent structures at the same time.
• It is necessary to have an extra and empty floor where the isolator will be applied (warehouse, parking lot, etc.). Otherwise, the floor on which the insulator is placed will not be insulated.
• Although the building itself will not be touched and the occupants will not need to evacuate their belongings, the occupants of the building will not be required to be in the building while the works are being carried out on the foundation of the building
• On the floor where the insulator will be applied, it is very likely that the structural elements will need to be strengthened.
• In order to clearly understand whether the structure is suitable for reinforcement with insulators, an expert team must first see the structure, then the strength checks of the structural elements should be made and the preliminary analyzes should be carried out by creating the static model of the structure. The strength of the building, the way of sitting and its architecture affect this whole process.
• Except for these items, the processes written for the standard structure are valid.
Q: 16, What are the prices of earthquake isolators?
A: There is no price list for earthquake isolation devices. The reason for this is that insulators are specially designed for each project and their sizes vary according to many factors. The dimensions of the insulators, and therefore their prices, vary depending on many factors such as the weight of the superstructure, the vertical load on each insulator, the seismicity of the area where the building is located, the concrete class used in the building, the performance target of the building, and the architecture. After determining the seismicity of the region with the preliminary static results of the project, a budgetary cost study can be carried out and prices can be calculated.
The most important point to be considered is that the structures to which earthquake isolators are applied can continue to be used immediately after the earthquake. This means that the structural and non-structural damage that will occur after a possible earthquake is completely prevented and possible repair costs will not be experienced, and this is a performance that can never be achieved in a structure designed without insulators. For example, people living in a house designed with earthquake insulators and applied correctly will be able to continue to live in their homes even after the expected maximum magnitude earthquake in the region, and will not bear any repair costs or the psychological burden of the earthquake.
You can reach the effects of the earthquake insulation application during the first construction phase and after a possible design earthquake.
Q: 17, What are the places where earthquake insulation cannot be applied?
A: Earthquake insulation cannot be applied to adjacent structures.
It is not correct to apply earthquake insulation in structures that have the risk of liquefaction.
It is not correct to apply earthquake insulation alone in very high and tower type structures. In this type of structures, applications should be done with extra damping devices.
Reinforcement projects begin with expert teams examining the existing structure and determining whether it is suitable for earthquake isolation and retrofitting.
All projects that are considered to apply earthquake insulation should start the project by consulting experts on the relevant subject beforehand.
Q: 18, What are the documents and certificates of Luzetech?
A: Our company has its own patented product as well as an integrated management system consisting of ISO 9001, ISO 14001 and ISO 45001. In addition, it has CE certificate for all its products and can produce in accordance with all national / international standards and specifications.
You can get touch with us or visit our websites for those files.
Q: 19, Where does Luzetech test the products?
A: We perform the tests of our products in house or in independent and/or accredited laboratories, which are accepted in the world and have the capacity to perform earthquake isolator tests.