Daily Maintenance Of Friction Pendulum Bearing (FPB): Core Tips For Service Life Extension

Apr 24, 2026 Leave a message

1. Routine Inspection (Once every six months)

  • Inspect the sealing components for damage and prevent ingress of dust, moisture and water vapor.
  • Check the bearing for displacement and corrosion, and verify the integrity of the slider surface.
  • Record displacement and load data, and compare with design values to identify abnormalities.

 

2. Periodic Maintenance (Once every 3–5 years)

  • Remove dust and contaminants from sliding surfaces and replace aged seals.
  • Test the friction coefficient and re-centering performance; replenish special wear-resistant grease when necessary. Mixing of different grease types is strictly prohibited.
  • Conduct anti-corrosion repair on corroded areas.

 

3. Post-earthquake Inspection (Implemented immediately after an earthquake)

  • Check the re-centering condition and measure residual displacement of the bearing.
  • Inspect the spherical surface and sliders for abnormal wear, cracks and damage.
  • Verify mechanical performance. The structure can only be put back into service after confirmed no functional failure.